Vickers V2010 1F13S3S 1CC12

Description & Features

Designed for power steering systems, small industrial units, and light press applications, the Vickers V2010 1F13S3S 1CC12 is a dual-displacement vane pump built around a pressure-balanced, modular 12-vane design. This configuration helps reduce noise and flow pulsation, making it well-suited for applications where consistent, smooth hydraulic output is required.

The pump is constructed from cast iron and operates within the V2010 series, offering a flow rate of approximately 99.77 litres per minute. Its modular architecture supports a wide range of available displacements, providing flexibility across different system configurations. Manufactured under the Eaton Vickers brand, this unit carries forward the engineering standards associated with the V10 and V20 vane pump platform.

SKU: 850100-3

Supplier Part Number (MPN): 850100-3

Specifications

Brand
Vickers by Danfoss
Cartridge Type
12 Design
Design Code
12
Dimensions
11.04 in L x 6.87 in W x 5 in H
Displacement
2.59 cu-in Shaft, 0.6 cu-in Cover
Drive Shaft Type
Square Keyed
Flow Rate
13 gpm Shaft, 3 gpm Cover
Housing Material
Iron
Inlet Port Type
4 Bolt Flanged
Maximum Operating Pressure
2200 psi Shaft, 2500 psi Cover
Mounting Type
2-Bolt Flanged
nmfc
77.50
Outlet Size
1-1/16-12, 3/4-16
Outlet Type
Threaded
Rotation Direction
Clockwise (Right Hand)
Seal Material
Buna-N
Segment Code
A
Series
V2010 Series
Speed Rating
2400 rpm Shaft, 3000 rpm Cover
Vane Type
Balanced

Product Questions & Answers (2)

Question by: Tammy M on Dec 21, 2025, 6:50 AM
flow rate on this unit is listed close to 100 liters a minute -- is that right for a V2010 series, or is that more than what most small press setups would actually see?
Answer by: Customer Support on Dec 22, 2025, 5:00 PM
For a V2010 series vane pump, a flow rate near 99.77 liters per minute is within the range this platform supports. Small press and industrial unit applications are listed uses for this pump, so the flow capacity lines up with what those setups typically need. Keep in mind actual output will vary based on your operating speed and system pressure, but the rated figure on this unit is not unusual for the V2010 configuration.
Question by: Ricky T on Aug 2, 2025, 11:04 AM
What kinda machines is this V2010 usually hooked up to?
Answer by: Customer Support on Aug 3, 2025, 8:34 PM
Typically, this vane pump finds itself useful in power steering systems, smaller industrial units, and even those little presses you see around.