DG4V-3(S) Series Subplate/Manifold Mount NFPA Size D03 Solenoid Valve, 4-Way, 3-Position, Spring Centered, Open Center, STD Performance, 12VDC DIN 43650 Coil.
DG4V-3(S) Series Subplate/Manifold Mount NFPA Size D03 Solenoid Valve, 4-Way, 3-Position, Spring Centered, Open Center, STD Performance, 12VDC DIN 43650 Coil.
This Eaton Vickers DG4V-3(S) Series subplate/manifold mounted solenoid valve is an NFPA Size D03, 4-way, 3-position valve with a spring centered, open center configuration and standard performance characteristics.
Designed with a gray iron body, this valve features a 12VDC DIN 43650 coil. It's suitable for use with fluids requiring a cleanliness level of 19/17/14 micron. The valve is designed for a maximum operating pressure of 5075 psi (Note: Pressures over 3000 PSI require a steel subplate or manifold.)
This model features Viton seals, a scratch-proof manual override, and allows coil changes without removing the valve. It is designed to be mounted to an ISO 4401 Size 03, NFPA D03 port interface.
SKU: 02-109044
Supplier Part Number (MPN): 02-109044
Alternate Part Numbers: C1AC34, DG4V3S0CMUG560
Specifications
Body Material
Gray Iron
Check Valve
No
Coil Rating
12VDC
Coil Type
DIN 43650
Design Code
60
Diode
No
Brand
DANFOSS POWER SOLUTIONS II LLC (VICKERS)
Brand
Danfoss Power Solutions
Pack Size
1.00
UOM
EA
Fluid Cleanliness
19/17/14 micron
Interface
ISO/DIS 4401-AB-03 D03
Leakage
Standard
Manual Override
Plain
Manual Override Option
No
Minimum Working Temperature
-20
Performance
Standard
Reducer Module
No
Spool Center Condition
A Port and Double Offset sensing switch on B Port
Spool Monitor Switch
None
Spring Arrangement
C
Stage
Single Stage
Supplier Part Number
02-109044
Switch Connector
No
Tank Port Rating
100
Type
STD
Valve Mount Type
Subplate/manifold mounted
Wattage
30
Product Weight
3.00 lbs
Alternate Part Numbers
Alternate Part NumberC1AC34, Alternate Part Number DG4V3S0CMUG560
DG4V-3S-0C-Y-M-SP2-G5-60DG4V-3(S) Series D03 Solenoid Valve
02-354934
STD
12VDC
Dual 6.3mm spade
Latching water-resistant manual overrides
DG4V-3S-0C-M-U-G5-60DG4V-3(S) Series D03 Solenoid Valve
02-109044
STD
12VDC
DIN 43650
Product Questions & Answers (1)
Question by: Brenda B on Sep 5, 2025, 2:47 PM
What kind of fluid is okay to run through this valve?
Answer by: Customer Support on Sep 7, 2025, 6:34 AM
This Eaton Vickers valve works with fluids requiring a cleanliness level of 19/17/14 micron, and can handle mineral oil between -4°F to 158°F or water-based fluids between +50°F to 129°F.