Double Wire Braid SAE 100R2AT Hose, 0.62 Inch ID, Up to 3625.00 PSI

Description & Features

Designed for hydraulic systems operating with petroleum-based, water-glycol, and lubricating oil fluids, the Double Wire Braid SAE 100R2AT Hose, 0.62 Inch ID, Up to 3625.00 PSI is a conductive, two-ply braided hose built to Eaton Aeroquip's GH793 Series standard. The 0.62-inch inner diameter and -10 dash size make it a common fit for mid-range hydraulic circuits requiring reliable pressure performance up to 3,625 PSI with compatible Global fittings.

The cover is a PVC/nitrile blend, providing standard abrasion resistance in typical industrial environments. Conductivity is built in, supporting static-dissipative requirements common in hydraulic applications. Burst pressure ratings vary depending on fitting selection, when paired with non-Global fittings, the burst rating decreases to 11,000 PSI.

SKU: GH793-10R250

Supplier Part Number (MPN): GH793-10R250

Alternate Part Numbers: C1CX68, GH793-10, GH793-10-100, MI-03077679, MINO-00015X60121

Specifications

Abrasion Resistance
Standard
Burst Pressure Note
Rating Applies for Global Fittings Only. For Other Fittings, Rating Decreases to 11000 psi
Conditional Temp Range
-40 to 257 deg F Intermittently
Conductivity
Conductive
Cover Material
Nitrile
Dash Size
10
For Use With
TTC/Z Series Hose Fittings
Hose Color
Black
Hose Type
Conductive
Impulse Cycle
200000
Inside Diameter
5/8 in
Lay Line Style
Ink Transfer
Package Form
Reel
Reinforcement
2-Wire Braided Brass-Plated Steel Wire
Resistance Properties
Abrasion
Segment Code
A
Series
GH793 Series
Tube Material
Nitrile

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Judy G on Jul 18, 2025, 11:08 AM
got a -10 line on a skid steer that sees about 3,000 psi. is this GH793 hose in the right ballpark?
Answer by: Customer Support on Jul 20, 2025, 8:08 AM
For pressure, you are in range. The GH793 in -10 size is rated up to 3,625 PSI for working pressure, so a 3,000 PSI circuit fits under that limit when the rest of the system is set up correctly.