Aeroquip R134A Refridgerant Hose

Description & Features

Designed for optimal performance in industrial cooling systems, the Aeroquip R134A Refrigerant Hose is engineered to meet SAE 100R5 standards, ensuring compatibility and reliability. This hose features a robust construction with a polyester cover and wire reinforcement, offering premium abrasion resistance. Its chlorobutyl tube material is specifically selected for its durability and resistance to low temperatures, capable of withstanding conditions as low as -40°F.

With a minimum bend radius of 5.5 inches, this hose provides flexibility without compromising strength, making it ideal for tight installations. The black color and dash size -10 enhance its adaptability in a range of applications, while the qualified 100R5 reusable hose fittings ensure ease of installation and maintenance. Weighing just 0.31 lbs, it is lightweight yet durable, making it a practical choice for demanding environments.

SKU: FC558-10

Supplier Part Number (MPN): FC558-10

Alternate Part Numbers: MI-03007880, MINO-00015F55877

Specifications

Abrasion Resistance
28
Alternate Part Numbers
Alternate Part Number MI-03007880, Alternate Part Number MINO-00015F55877
Certifications
SAE 100R5
Color
Black
Cover Material
Polyester
Dash Size
-10
Brand
Danfoss Power Solutions (II LLC Aeroquip)
Brand
Aeroquip
Pack Size
12.00
UOM
FT
ICC
Hoses and Flexible Tubes
Language
English
Minimum Bend Radius
5.50
Minimum Bend Radius
5.5
Minimum Working Temperature
-40
Product Width
0.92
Qualified Hose Fittings
100R5 Reusable
Reinforcement Material
Wire
Supplier Part Number
FC558-10
Tube Material
Chlorobutyl
Product Weight
0.31 lbs

Product Questions & Answers (3)

Question by: Brett B on Jan 8, 2026, 10:07 AM
got a tight spot to snake a line through. how tight can this hose bend without kinking up on me?
Answer by: Customer Support on Jan 9, 2026, 4:13 PM
For routing, the minimum bend radius is 5.5 inches. Keeping your bend at or above that radius helps it stay flexible without stressing the reinforcement.
Question by: Ray H on May 25, 2025, 7:09 PM
how tight a bend can you make with this hose before it starts kinking up on you?
Answer by: Customer Support on May 27, 2025, 8:21 AM
Minimum bend radius on this one is 5.5 inches, so keep your routing at or above that and you won't have any kinking issues. If you're working a tight spot under a unit, plan your path before you commit so you're not fighting it after the fittings are already on.
Question by: Gary P on Jun 25, 2025, 10:06 AM
Will this hose work with R134A refrigerant without breaking down?
Answer by: Customer Support on Jun 26, 2025, 12:05 PM
Engineered specifically for R134A refrigerant, this Aeroquip hose uses a chlorobutyl tube material designed to resist degradation from that particular refrigerant.