The Eaton Aeroquip Flexmaster Series Danfoss / Eaton Flexmaster Tube and Pipe Joints Coupling is designed for reliable pipe and tube connections in industrial settings. With its bulged, straight-through design, each joint accommodates angular misalignment up to 4° per end, ensuring flexibility during installation. These joints are available in both standard and self-restrained styles, featuring a stainless steel gripping ring within each gasket to prevent movement along the pipe or tube.
Built to handle service pressures up to 300 psi, the Flexmaster joints provide robust performance across various applications. It is essential to use normal hangars, guides, and anchors, as these joints are not intended to hold piping systems together independently. The coupling fits line, hose, and tube ends, offering versatile compatibility for diverse hydraulic systems.
Danfoss / Eaton Flexmaster Tube and Pipe Joints Coupling
NH100085-250YFFlexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Coupling
NH100085-400YFFlexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Coupling
NK1000023-200Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Retainer
NK1000023-400Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Retainer
NK1000061C350Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Gasket Assembly
NK1000063C200Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Gasket
NK1000063C250Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Gasket
NK1000063C300Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Gasket
NK1000063C400Flexmaster Series Part
Danfoss / Eaton Flexmaster Tube and Pipe Joints Gasket
Product Questions & Answers (2)
Question by: Kurt J on Jun 29, 2025, 2:19 PM
How much give is there in one of these? I need a little wiggle room in my setup.
Answer by: Customer Support on Jul 1, 2025, 6:56 AM
These Flexmaster joints can handle up to 4 degrees of angular misalignment per end. That should give you a little bit of play during installation.
Question by: Cindy H on Mar 31, 2026, 9:59 AM
got a little misalignment on my run, how much angle will these Flexmaster joints tolerate?
Answer by: Customer Support on Apr 2, 2026, 6:09 AM
For the bulged, straight-through Flexmaster joints, they will take up to 4 degrees of angular misalignment per end, which helps when the pipe or tube is not lined up perfect during install.