GF Series Positive Displacement Flow Meters with Conditioned Output GF070-MAP-S-6 | FT10889-07

Description & Features

The WEBTEC GF Series Positive Displacement Flow Meters are engineered to provide accurate flow measurement for hydraulic systems, accommodating a flow range from 0.5 to 70 L/min (0.15 to 19 US gpm) with an impressive accuracy of ±0.5% within the 15–100% range. Designed to withstand harsh conditions, they operate under pressures up to 420 bar (6000 psi) and fluid temperatures between -40 to 120°C (-40 to 284°F). With a stainless steel body and internal components, these meters ensure durability and reliability in challenging applications.

Equipped with a 1-1/16" -16UN JIC Male porting and an M12 5-Pin electrical connection, the flow meters are versatile and easy to integrate into existing systems. The IP65 rating provides excellent protection against dust and water ingress. Compatible with mineral oils to ISO 11158 and other fluids on request, these meters are suitable for a wide range of industrial applications.

SKU: FT10889-07
Supplier Part Number (MPN): GF070-MAP-S-6

Specifications

Brand
WEBTEC
Brand
Webtec
Pack Size
1.00
UOM
EA
Supplier Part Number
FT10889-07
Flow Accuracy
±0.5% of Reading (15–100% range)
Ambient Temperature
5 to 40° C, 41 to 104 °F
Body Materials
Stainless Steel
Compatible Fluid
Mineral oils to ISO 11158 (other fluids on request)
Connection Type
M12 5-Pin
Flow Range (US gpm)
0.15 - 19
Flow Range (L/min)
0.5 - 70
Fluid Temperature Range
-40 to 120°C, -40 to 284°F
Gross Weight
9.5 kg, 21 lbs
Internal Materials
Stainless Steel
IP Rating
IP65
Maximum Rated Flow
70 L/min, 19 US gpm
Max Rated Pressure
420 bar, 6000 psi
Net Weight
9.1 kg, 20 lbs
Porting
1-1/16” -16UN JIC Male
Power Supply
15 – 30 V DC
Seals
NBR
Product Weight
0.99 lbs

Product Questions & Answers (2)

Question by: Frank C on Jul 27, 2025, 8:29 PM
accuracy on this thing -- is it consistent across the whole flow range or does it fall off at the low end?
Answer by: Customer Support on Jul 29, 2025, 6:32 PM
At the lower end of the range, below 15% of max flow, accuracy isn't rated the same way. From 15% up to 100% of the rated flow, you're looking at plus or minus 0.5% of reading, which is solid for a positive displacement meter. Below that threshold, the 0.5% figure doesn't apply, so if your application regularly runs under about 10 liters per minute, that's worth factoring in. The 0.5 to 70 L/min total range gives you plenty of headroom for most hydraulic test and monitoring work, but the rated accuracy window starts at roughly 10.5 L/min.
Question by: Nancy S on Jun 26, 2025, 3:24 PM
What kind of fluids can be used with the GF Series Positive Displacement Flow Meter?
Answer by: Customer Support on Jun 28, 2025, 9:36 AM
This flow meter is suitable for use with mineral oils that meet the ISO 11158 standard. If you need to use it with other fluids, be sure to check for compatibility or request additional information from the supplier.

Tell us what you need and we'll get back to you.