CT Series Turbine Flow Meters with Conditioned Output CT300-CAN-B-B-6 | FT9503-24

Description & Features

The WEBTEC CT Series Turbine Flow Meters with Conditioned Output excel in providing accurate flow measurement for hydraulic systems. Designed to handle a maximum flow rate of 300 L/min (80 US gpm) and withstand pressures up to 420 bar (6000 psi), these meters offer reliable performance in demanding environments. Their flow accuracy of ±1% full scale ensures precise readings, making them ideal for critical applications. With a fluid temperature range from 5 to 90°C (41 to 194°F) and compatibility with mineral oils to ISO 11158, they offer versatility across various hydraulic fluids.

Constructed with durable materials such as aluminum, steel, and stainless steel, the CT300-CAN-B-B-6 model is built to last. Featuring an IP66 rating, it is protected against dust and water ingress, making it suitable for harsh conditions. The M12 5-Pin electrical connection and 12–32 V DC power supply ensure easy integration into existing systems, while the compact design, weighing 1.7 kg, facilitates installation and handling.

SKU: FT9503-24
Supplier Part Number (MPN): CT300-CAN-B-B-6

Specifications

Brand
WEBTEC
Brand
Webtec
Pack Size
1.00
UOM
EA
Supplier Part Number
FT9503-24
Flow Accuracy
±1% Full Scale
Temperature Accuracy
±2°C / ±4°F
Ambient Temperature
5 to 40°C, 41 to 104°F
Body Materials
Aluminium
Compatible Fluid
Mineral oils to ISO 11158 (other fluids on request)
Connection Type
M12 5-Pin
Flow Range (US gpm)
2 - 80
Flow Range (L/min)
8 - 300
Fluid Temperature Range
5 to 90°C, 41 to 194°F
Gross Weight
2 kg, 4.4 lbs
Internal Materials
Aluminium, Steel, Stainless Steel
IP Rating
IP66
Maximum Rated Flow
300 L/min, 80 US gpm
Max Rated Pressure
420 bar, 6000 psi
Net Weight
1.7 kg, 3.7 lbs
Porting
Main 1” BSPP. Top 1/4” BSPP
Power Supply
12 – 32 V DC
Seals
FKM / EPDM
Product Weight
0.99 lbs

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Shawn W on Nov 24, 2025, 11:14 AM
flow range on this one goes down to 8 L/min, is that the lower cutoff or just where accuracy starts to fall off?
Answer by: Customer Support on Nov 25, 2025, 12:59 PM
For the CT300-CAN-B-B-6, 8 L/min is the bottom of the rated flow range, so that is where the meter is designed to operate reliably. Below that threshold, the turbine may not spin consistently enough to return dependable readings. The upper end tops out at 300 L/min, or 80 gpm if you are working in imperial. Accuracy across that range is rated at plus or minus 1% of full scale, which holds within the stated operating band rather than degrading gradually toward the low end.

Tell us what you need and we'll get back to you.