Designed for use with Concentric GC8000 and GC8001 Series DC hydraulic power unit kits, this single pilot-operated check valve component supports controlled fluid flow management in compact power unit configurations. The GC8001 Series JBS Single PO CHECK is manufactured by Concentric AB under the Concentric Rockford brand and is identified by catalog number C1EL86.
Pilot-operated check valves of this type are commonly used in mobile and stationary hydraulic circuits where load holding and controlled reverse flow are required. This component is suited for integration within DC-powered hydraulic power units used across a range of industrial and mobile equipment applications.
SKU: 1300727
Supplier Part Number (MPN): 1300727
Alternate Part Numbers: C1EL86
Loading related products…
Specifications
Brand
Concentric Rockford Inc
Brand
Concentric Rockford
Pack Size
1.00
UOM
EA
Supplier Part Number
1300727
Alternate Part Numbers
Alternate Part NumberC1EL86
Product Weight
1.36 lbs
Similar Products
Model Number
Product Description
Price
Action
1300727GC8001 Series DC HPU Kit
JBS SINGLE PO CHECK
1300740GC8001 Series DC HPU Kit
CONCENTRIC AB 12VDC VALVE COIL
1300743GC8001 Series DC HPU Kit
JS BARNES CART DCV ADP KT
1300785GC8001 Series DC HPU Kit
CONCENTRIC/HALDEX CARTRIDGE VALVE
1300985GC8001 Series DC HPU Kit
BARNES HE2000 RELIEF VALVE
1300744GC8001 Series DC HPU Kit
JS BARNES VALVE ADAPTER
2380322GC8001 Series DC HPU Kit
DOUBLE ACTING REMOTE PENDENT FOR 4 WAY 3
Product Questions & Answers (2)
Question by: Johnny G on Mar 8, 2026, 3:40 PM
got a Concentric GC8000 power unit kit, is this the right check valve for it?
Answer by: Customer Support on Mar 10, 2026, 7:32 AM
Built for the Concentric GC8000 and GC8001 Series power unit kits, the GC8001 Series JBS Single PO CHECK is the matching check component for those kits.
Question by: Peggy R on Jan 10, 2026, 8:38 PM
what exactly is a "PO check" on one of these power unit kits, and what's it doing in the system?
Answer by: Customer Support on Jan 12, 2026, 6:38 AM
A pilot-operated check valve holds load pressure in one direction and only allows flow back through when a pilot signal tells it to open. On a DC hydraulic power unit like the GC8001 series, that means your cylinder or actuator stays put when the pump isn't running. No creep, no drift. It's a pretty common setup on lift and dump applications where you need the load locked in position between cycles.