H Series Geroter Motors, Up To 4600 lb-in Intermittent Torque, 1100 Intermittent RPM

Description & Features

Fluid Viscosity Minimum viscosity (at operating temperature) should be the highest of the following: 100SUS or (20 x PSI)/RPM = SUS.
Maximum Case Pressure 1500 PSI.
Maximum Operating Temperature 180° F.
Recommended Break-In To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.
Recommended Filtration Per ISO Cleanliness Code, level 18/13.
Recommended Fluids Premium quality, anti-wear type hydraulic fluid.

Products

Product Questions & Answers (1)

Question by: Dwight W on May 18, 2025, 2:00 PM
What kind of hydraulic fluid do these motors need? Don't wanna mess anything up by using the wrong stuff.
Answer by: Customer Support on May 19, 2025, 2:08 PM
These motors work best with premium quality, anti-wear type hydraulic fluid. Also, to keep things running smoothly, aim for an ISO Cleanliness Code level of 18/13 for your filtration.