Engineered by Ultra Clean Tech Corp, the UC22 is a specialized cleaning projectile designed for hose, tube, and pipe systems with an inner diameter of 0.87 inches. This versatile solution is ideal for applications across hydraulic and pneumatic lines, fuel lines, food and beverage lines, steam pipes, heat exchangers, condensers, air conditioning, and refrigeration systems.
The launcher unit features a locking faceplate that pivots away from the body for quick and easy nozzle size changes. O-Ring seals ensure positive sealing, and an air inlet port comes equipped with a quick disconnect coupling. The trigger mechanism allows precise firing of the projectile, providing efficient cleaning.
Recommended for hose IDs of 5/8 inches and tube/pipe ODs such as H16, the UC22 can operate within a pressure range of 85 PSI to 150 PSI. Various nozzle sizes are available in four basic styles: hose & pipe, JIC, tube, and BSP, accommodating a broad spectrum of needs.
Contact us for launcher and nozzle information, and for assistance with application-specific requirements.
Supplier Part Number: UC22
MPN: C1ZS65
Loading related products…
Specifications
Brand
Ultra Clean®
Diameter
0.8661 in ID
Series
UC Series
Sg Launcher Unit
Locking Faceplate Pivots Away from Body for Easy Nozzle Size Change, O-ring Seals are Used for Positive Sealing, Air Inlet Port with Quick Disconnect Coupling, Trigger Mechanism for Firing Projectile
Sg Nozzles
A Wide Range of Nozzle Sizes are Available in Four Basic Styles, Hose and Pipe - the Nozzle is Inserted into the Hose or Pipe, JIC - the Male Flared End of the JIC Nozzle Butts Against the Female Flare of the Hose or Tube Fitting, Tube - the Nozzle is Ins
Sg Sizing
To Clean an ID of 2 in or Less, the OD of the Projectile Should be Approximately 20% Larger than the ID if ID is Larger than 2 in, Projectile Should be Approximately 10% Larger than the ID (Individual Circumstances May Require A Smaller or A Larger Projec
trying to clean out some 5/8 inside diameter hydraulic hose. what is the rule of thumb for sizing these things so they actually scrub the walls?
Answer by: Customer Support on Aug 22, 2025, 4:36 PM
Getting the right fit relies on a simple calculation. For any line with an inside diameter of 2 inches or less, the outside diameter of the projectile needs to be approximately 20 percent larger than the hose inside diameter. The extra size gives the plug enough compression to wipe the inside walls effectively as it travels.
Question by: Neil P on Mar 27, 2025, 12:43 PM
Will these projectiles work in different size hoses?
Answer by: Customer Support on Mar 29, 2025, 10:19 AM
These projectiles are designed for a 0.87 inch inner diameter hose. You'll want to match the projectile size to your hose ID for best cleaning.
Question by: Keith S on Jan 8, 2026, 6:58 PM
i’ve got hose that measures right at 0.87 on the inside, is UC22 the right cleaning “slug” for that size?
Answer by: Customer Support on Jan 10, 2026, 6:34 PM
For a hose or tube with about a 0.87 inch inside diameter, the UC22 projectile matches that target size, with a listed I.D. of 0.8661 inch. It is also called out for use with a 5/8 inch hose I.D. nozzle and a tube or pipe OD noted as H16.
Question by: Ralph S on Apr 15, 2025, 6:26 PM
these come in packs of 100, right? just want to make sure before i order cause we go through em pretty quick on the food processing lines
Answer by: Customer Support on Apr 17, 2025, 4:54 PM
the UC22 projectiles come 100 per package. For high-volume cleaning use like food and beverage lines, that quantity tends to work out well since you'll be running these regularly to keep things flushed and flowing.