CT Series Turbine Flow Meters with Conditioned Output CT300-5V-S-S-6 | FT9503-06

Description & Features

Part of WEBTEC's CT Series, this turbine flow meter is designed for accurate hydraulic flow measurement across a working range of 8 to 300 L/min (2 to 80 US gpm), with a rated accuracy of ±1% full scale. It withstands system pressures up to 420 bar (6,000 psi) and handles fluid temperatures from 5 to 90°C (41 to 194°F), making it suitable for demanding industrial hydraulic service.

The conditioned 5 V output is delivered via an M12 5-pin connector, with a power supply requirement of 12 to 32 V DC. Main porting is 1-5/16" -12UN #16 SAE ORB, with a top port at 7/16" -20UN #4 SAE ORB. The aluminium body incorporates steel and stainless steel internals with FKM/EPDM seals, and the unit carries an IP66 rating for reliable use in wet or dirty environments. Compatible with mineral oils to ISO 11158, with a net weight of 1.7 kg (3.7 lbs).

SKU: FT9503-06
Supplier Part Number (MPN): CT300-5V-S-S-6

Specifications

Brand
WEBTEC
Brand
Webtec
Pack Size
1.00
UOM
EA
Supplier Part Number
FT9503-06
Flow Accuracy
±1% Full Scale
Ambient Temperature
5 to 40°C, 41 to 104°F
Body Materials
Aluminium
Compatible Fluid
Mineral oils to ISO 11158 (other fluids on request)
Connection Type
M12 5-Pin
Flow Range (US gpm)
2 - 80
Flow Range (L/min)
8 - 300
Fluid Temperature Range
5 to 90°C, 41 to 194°F
Gross Weight
2 kg, 4.4 lbs
Internal Materials
Aluminium, Steel, Stainless Steel
IP Rating
IP66
Maximum Rated Flow
300 L/min 80 US gpm
Max Rated Pressure
420 bar, 6000 psi
Net Weight
1.7 kg, 3.7 lbs
Porting
Main 1-5/16” -12UN #16 SAE ORB, Top 7/16” -20UN #4 SAE ORB
Power Supply
12 – 32 V DC
Seals
FKM / EPDM
Product Weight
0.99 lbs

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Carl B on Sep 9, 2025, 4:07 PM
what's the usable flow range on this thing, and how tight is the accuracy across that span?
Answer by: Customer Support on Sep 11, 2025, 7:59 AM
Reads from 8 to 300 L/min, or 2 to 80 US gpm if you're working in those units. Accuracy holds at plus or minus 1% of full scale across that range. Worth keeping in mind that 1% full scale means the error budget is calculated against 300 L/min, not against whatever your actual reading is at a given moment, so at the low end of the range that margin represents a larger slice of the measured value.
Question by: Clint M on Nov 27, 2025, 7:34 PM
How well does the CT300-5V-S-S-6 handle different fluid temperatures?
Answer by: Customer Support on Nov 29, 2025, 12:04 PM
The CT300-5V-S-S-6 operates efficiently with fluid temperatures ranging from 5 to 90°C (41 to 194°F), making it suitable for a variety of hydraulic systems that use mineral oils compliant with ISO 11158.