MPV1-10 Series 2-Way, 2-Position Pull-To-Open Manual Catridge Valves, Up To 3000 PSI & 12 GPM

Description & Features

Application For on-off control of a single stream of fluid. Pull-to-open. Release to close (spring returns valve to closed).
Cartridge Model MPV1-10*, sold separately.
Features Cartridge style (Requires a machined cavity or housing for installation). Pull-to-open knob.
Flow Rating 12 GPM.
Housing Cavity size C-10-2, sold separately, see
Maximum Operating Pressure 3000 PSI.
Recommended Filtration ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Temperature Range -40°F to 248°F (Extreme Limits).

Products

Product Questions & Answers (1)

Question by: Jerry S on Mar 27, 2026, 3:52 PM
If I pull the knob, will it stay open? I need it to stay open for a bit while I do some work.
Answer by: Customer Support on Mar 29, 2026, 6:59 AM
No, it won't stay open on its own. When you release the knob, the spring returns the valve to the closed position automatically. It's designed for on-off control where it's only open when you're actively pulling.