DANFOSS / EATON FLEXMASTER - CODE FX

Description & Features

Designed for industrial hydraulic tube and pipe joint applications, this Buna-N gasket assembly supports quick connect and disconnect functionality, making maintenance and component replacement more straightforward in demanding environments. It is rated for a minimum working temperature of -30°C, making it suitable for use in cold-condition hydraulic systems. The Danfoss / Eaton Flexmaster - Code Fx is a size 6 x 6 line/hose/tube fitting that absorbs machine vibration, reducing stress on connected components during operation. Manufactured under the Danfoss Power Solutions (Aeroquip) brand, this assembly carries an EAR99 export classification and is available with a standard lead time of 7 days.

SKU: NK1000061C600

Supplier Part Number (MPN): NK1000061C600

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00925X14350
Brand
Danfoss Power Solutions (II LLC Aeroquip)
Brand
Aeroquip
Pack Size
1.00
UOM
EA
End Size 1
6
End Size 2
6
End Type 2
Line/Hose/Tube
Features
Quick connects and disconnects|Simplifies maintenance and repairs|Absorbs machine vibration
ICC
Tube and Pipe Joints
Item Type
Flexmaster Gasket
Language
English
Minimum Working Temperature
-30
Net Pack Quantity Units
EA
NMFC
50
Product Material
Buna-N
Product Width
7.88
Sub Brand
Flexmaster
Supplier Part Number
NK1000061C600
Product Weight
0.67 lbs

Product Questions & Answers (3)

Question by: Norm W on Oct 2, 2025, 12:28 PM
got a flexmaster gasket in hand that says code FX. is this the buna-n one for tube and pipe joints, or am i mixin parts up
Answer by: Customer Support on Oct 4, 2025, 6:28 AM
Code FX on this Flexmaster gasket assembly matches the Buna-N material version meant for industrial hydraulic tube and pipe joint applications.
Question by: Sherry R on Sep 5, 2025, 1:39 PM
gasket material on this one -- is it buna-n or something else? got some cold weather conditions to deal with and don't want to order the wrong thing
Answer by: Customer Support on Sep 7, 2025, 6:53 AM
Buna-N is the material, and it holds up down to -30°C, so cold-condition hydraulic systems are well within its range. For most cold-weather industrial setups, that lower temperature rating covers a pretty wide range of real-world operating conditions.
Question by: Brent P on Nov 2, 2025, 6:04 AM
What's the coldest temp this thing can handle?
Answer by: Customer Support on Nov 3, 2025, 6:38 AM
The minimum working temperature for this Flexmaster gasket is -30°C.