PE17 Series Single-Phase 2-Speed Pump, Motor, Remote On-Off Motor Control (24VDC), 10 ft, Valve, Pump on to extend, off to hold, off & manually shift valve to return

Description & Features

The SPX Hydraulic Technologies PE17 Series Single-Phase 2-Speed Pump is designed for use with single-acting cylinders in maintenance and construction applications. This hydraulic pump is suitable for operating pressures up to 10,000 psi.

Equipped with a 1/2 hp, 3,450 rpm, single-phase, thermal-protected induction motor, the PE17 Series 2-Speed Pump features a remote on/off motor control with a 10 ft cord, and operates at a quiet 67-81 dBA noise level. It has a flow rating of 290 in³/min at 0 PSI, 190 in³/min at 100 PSI, 20 in³/min at 5,000 PSI, and 16 in³/min at 10,000 PSI. Current draw is 10 amps at 115VAC.

SKU: PE172-50-220

Supplier Part Number (MPN): PE172-50-220

Alternate Part Numbers: C1JQ22

Specifications

Control
Remote On-Off Motor Control (24 VDC), 10 ft
Cylinder Compatibility
Single-Acting, Double-Acting
For Use With
Single Acting Cylinders
Function
Pump on to Extend, Off to Hold, Off and Manually Shift Valve to Return
grp Current Draw 10000 Psi
10 A at 115 VAC
Material
Thermoplastic
Maximum Operating Pressure
10000 psi
Number of Outlets
1
Pump Control Type
Remote
Series
PE17 Series
Valve Function
Advance, Return
Valve Operation
Manual
Valve Type
2-Position, 2-Way

Product Questions & Answers (3)

Sign In Hover me Please sign in to submit a question
Question by: Danny H on Jul 19, 2025, 4:10 PM
got a single-acting ram for some maintenance work. how’s this pump set up to hold and then let the cylinder back down
Answer by: Customer Support on Jul 21, 2025, 10:09 AM
For extend and hold, the valve function is pump on to extend, then off to hold. To return, you shut the pump off and manually shift the valve to send the cylinder back.
Question by: Janice G on May 3, 2025, 1:25 PM
running this off a small generator on the job site, will 10 amps at 115 volt be enough or am I gonna need something bigger?
Answer by: Customer Support on May 4, 2025, 3:20 PM
Ten amps at 115VAC is the full current draw for this pump, so a small generator should handle it without much trouble. The low amperage draw is actually one of the reasons this unit gets used in field situations where you're working off limited power. Just make sure your generator can sustain that load under the startup demand, since this motor is rated to start under full load.
Question by: Stan T on Jul 27, 2025, 7:49 AM
Will this pump work okay with a single acting cylinder?
Answer by: Customer Support on Jul 28, 2025, 7:14 PM
Yes, this SPX Hydraulic Technologies PE17 Series pump is designed for use with single-acting cylinders.