This Eaton Vickers RV5-10 Series Pilot-Operated Spool Type Relief Cartridge Valve is designed for use in harvesters, refuse haulers, and other mobile and industrial applications. This screw-in cartridge valve requires a machined cavity or housing for installation (C-10-2 cavity size).
The RV5-10 Series cartridge valve provides reliable and economical pressure control with smooth, quiet, continuous duty performance. It features a 250-3500 PSI adjustable range (set at 1400 PSI) and a maximum flow rate of 30 GPM. The recommended filtration level is 18/16/13 microns.
SKU: 02-180537
Supplier Part Number (MPN): 02-180537
Alternate Part Numbers: C1MX11
Loading related products…
Specifications
Adjustable Range
250-3500 (Set at 1400)
Adjustment
No
Adjustment Style
Screw
Application
Harvesters, refuse haulers, mobile and industrial applications
Check Valve
No
Diode
No
Brand
Danfoss – Hydraulics
Brand
Danfoss Power Solutions
Pack Size
1.00
UOM
EA
Electrical Flag
No
Features
350 bar (5000 psi) & 300 L/min (80 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Housing
None
Installation Type
Screw-in Cartridge
Leakage
114 cc/min
Minimum Working Pressure
17
Number of Housing Ports
2
Number of Valve Ports
2
Operation
Pilot Operated
Port Type
Cartrige Only
Recommended Filtration Level
18/16/13 microns
Remote Control
No
Seal Material
Buna-N
Seal Type
Buna-N
Special Features
None
Style
Spool
Supplier Part Number
02-180537
Switch Connector
No
Valve Material
Cartridge only
Alternate Part Numbers
Alternate Part NumberC1MX11, Alternate Part Number MINO-00900X13267
Is there supposed to be a housing included with this valve?
Answer by: Customer Support on Jan 21, 2026, 4:44 PM
Nope, this is just the cartridge valve itself. You'll need to order the housing separately, and make sure it's a C-10-2 cavity size.
Question by: Kirk F on Jun 7, 2025, 1:04 PM
Does this valve come with a housing, or is that something I gotta source separate?
Answer by: Customer Support on Jun 8, 2025, 1:36 PM
The cartridge is sold on its own, no housing included. You'll need a machined cavity or housing to install it. The cavity size you're looking for is C-10-2, which is sold separately. Worth knowing before you order so you're not waiting on parts when it's time to put it in.