This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. This valve is used in applications requiring low leakage, such as load holding applications or as a general purpose diverter or dump valve.
Flow Rating
30 GPM.
Housing
Cavity size C-12-2 or C-12-2U sold separately. Add “U” after number if undercut is required. If undercut is not specified, expect 10 PSI @ 15 GPM and 20 PSI @ 30 GPM higher pressure drop, see
Internal Leakage
Port 2 to Port 1: Less than 5 drops/min, max @ 3000 PSI.
Note
Performance data is typical with fluid at 105 SSU and 120°F.
Operation
In the de-energized position the valve blocks flow from port 2 to 1 and free flow is allowed from port 1 to 2. When the solenoid is energized the pilot poppet is pulled off the seat allowing the valve to open in both directions.
Pressure Rating
3000 PSI.
Recommended Filtration
ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Solenoid Connectors
(Required on models that use DIN 43650 connectors).
Temperature Range
-40° to 248°F (Extreme Limits).
Products
Model Number
Part Number
Housing
Coil
Seal Material
Price
Action
SV3-12-C-0-00SV3-12-C Series Cartridge Valve
02-161062
None
Not Included
Buna-N
Product Questions & Answers (1)
Question by: Bobby M on Feb 4, 2026, 6:24 AM
If I get the housing without the undercut, how much extra pressure drop am I looking at when running this valve at its max flow rate?
Answer by: Customer Support on Feb 6, 2026, 6:05 AM
Expect around 20 PSI higher pressure drop when running the valve at 30 GPM if you skip the undercut. It'll be about 10 PSI higher at 15 GPM.