SystemStak Pilot-Operated Check Valve, NFPA-D03 Size, Dual Pilot Check, 14.5 PSI Cracking Pressure, 3:1 Pilot Ratio

Description & Features

This pilot-operated check valve from Danfoss (Power Solutions II LLC) is designed to meet NFPA-D03 standards. It incorporates dual pilot checks and a cracking pressure of 14.5 PSI with a pilot ratio of 3:1.

Constructed with a ductile iron body and hardened steel internal parts, this valve ensures durability and high performance. The rugged design features large flow passages, enabling high flow rates and pressure up to 4500 PSI.

The SystemStak valve aims to save installation time and reduce potential leaks thanks to its standard interface and stacked configuration. The fluid temperature ranges are suitable for petroleum oil and water-based fluids, offering versatility for various applications.

Ambient temperature functionality ranges from -4deg;F to 176deg;F, making this valve suitable for extreme environments. The valversquo;s stacking height is 1.57 inches and it includes standard Vitonreg; seals and aluminum nameplates for easy identification.

Recommended filtration requirements are ISO level 20/16 up to 3000 PSI, and ISO level 18/14 for pressures over 3000 PSI, ensuring clean hydraulic operations.

MPN: DGMPC-3-ABK-BAK-41

Supplier Part Number: 694400

Specifications

Actuator Type
Pressure Operated
Available Function
Relief, Counterbalance, Sequence, Pressure Reducing, Direct Check, Pilot-Operated Check, Flow Control
Body Material
Iron
Design
41 Series
Dimensions
3.82 in L x 1 in W x 1.57 in H
Domestic/Import
Domestic
Function
Check in Line A, Pilot Operated From Line B
Function Dual
Check in Line B, Pilot Operated From Line A
Key
A
Material Standard
ANSI B93.7M-D03
Media
Petroleum Oil
Mounting Type
Manifold, Subplate
Nominal Size
#03
Performance
Standard-Performance
Pilot Ratio
3:1
Seal Material
FKM
Series
DGMPC-3 Series

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Howard P on Dec 2, 2025, 5:45 PM
How does the 3:1 pilot ratio affect the valve's operation?
Answer by: Customer Support on Dec 4, 2025, 11:16 AM
The 3:1 pilot ratio in this SystemStak Pilot-Operated Check Valve means that the pilot pressure needs to be three times higher than the load pressure to open the check valve. This ratio helps ensure the valve opens only when necessary, providing reliable operation in hydraulic systems.