Type S3 3000 PSI Bottom-Repairable Accumulators, Up To 3000 PSI

Description & Features

Application Uses include supplementing pump flow, reduction of installed power, providing a standby source of fluid energy, shock absorption and surge dampening.
CAUTION Precharge with dry nitrogen gas only. Never operate accumulator without proper precharge. Release all system pressure and stored pressure before attempting any maintenance or service.
Features Bottom repairable style. Design factors exceed the requirements of all standard codes. Each vessel individually tested and registered. Integrated pressure relief design. Cannot be disassembled under pressure.
Maximum Operating Pressure 3000 PSI.
Temperature Range Buna-N Bladder: 35°F to 160°F (Optimal Range). -10°F to 210°F (Peak Range).

Products

Product Questions & Answers (1)

Question by: Warren O on Jan 20, 2026, 9:48 AM
What kind of operating temps can this thing handle without pooping out?
Answer by: Customer Support on Jan 21, 2026, 8:27 PM
This accumulator is designed with a Buna-N bladder that works best between 35°F and 160°F, but it can handle peaks from -10°F to 210°F.