The V2010 Series Double Vane Pump from Danfoss Power Solutions features a highly efficient pressure-balanced 12-vane modular design. This industrial-grade pump is engineered to minimize noise and flow pulsation optimizing performance for power steering small industrial units and small presses. It is rated for a maximum pressure of 2500 PSI and a speed of 2800 RPM making it suitable for demanding applications.
The pump utilizes a 7/8" keyed shaft and operates with counterclockwise (CCW) rotation. Built with Buna-N seals it supports durable and reliable use in various harsh environments. It offers two outlet positions (A/D) and includes a 2-bolt SAE B flange mount for secure installation.
With front and rear displacements of 1.81 and 1 cubic inches respectively this dual pump configuration ensures versatile and consistent hydraulic performance. The inlet port features a 1-1/2 inch Code 61 flange while the front and rear pump outlets come with SAE-16 and SAE-8 straight threads.
Model Number: V2010-1F9S5S-1AD-12L-167
Supplier Part Number: 721AR00033A
Loading related products…
Specifications
Brand
Vickers by Danfoss
Cartridge Type
12 Design
Configuration
Double
Design Code
12
Dimensions
11.65 in L x 6.87 in W x 5 in H
Displacement
1.81 cu-in Shaft, 1 cu-in Cover
Drive Shaft Type
Square Keyed
Flow Rate
9 gpm Shaft, 5 gpm Cover
grp Features
Vickers balanced vane construction. Buna-N seals standard. Shaft rotation can be changed by changing the assembly of internal parts
V2010-1F7S3S-1CC-12L-167V2010 Series Double Vane Pump
721AR00032A
7/8 Keyed
2-Bolt SAE B
7/3
10.5
2500
3000 RPM
CCW
4.5
1.39
0.6
V2010-1F9S3S-1BA-12L-167V2010 Series Double Vane Pump
721AR00034A
7/8 Keyed
2-Bolt SAE B
9/3
13.5
2500
2800 RPM
CCW
4.5
1.81
0.6
Product Questions & Answers (2)
Question by: Shawn S on Nov 30, 2025, 7:17 PM
pump says CCW rotation -- is that something that can be flipped or are you stuck with it?
Answer by: Customer Support on Dec 1, 2025, 9:19 PM
Shaft rotation on these Vickers-style vane pumps can actually be changed by disassembling and reassembling the internal components in the opposite orientation. So CCW isn't permanent if your setup calls for something different. Just know that it does require taking the pump apart to do it, it's not a simple external switch or setting.
Question by: Daryl P on Apr 27, 2025, 10:06 AM
What kind of machines is this pump good for?
Answer by: Customer Support on Apr 28, 2025, 7:41 PM
This double vane pump is intended for power steering, small industrial units, and small presses.