Salami VD10A-VD12A R2 DETENT Kit

Description & Features

The Salami VD10A-VD12A R2 Detent Kit is engineered for optimal performance within a temperature range of -4deg;F to 185deg;F using standard NBR seals. Suitable for applications requiring a flow rating of 32 GPM, this kit ensures reliable performance and efficiency.

With a maximum operating pressure of 4000 PSI on ports "P" and 4500 PSI on ports "A" and "B", it meets the demanding requirements of industrial systems. The internal leakage rate ranges from 2.43 to 3.34 insup3;/min. at 2285 PSI, maintaining system integrity.

Designed by Salami S.p.A, this kit supports fluid viscosities ranging from a minimum of 10 cSt to a maximum of 460 cSt, with optimal performance between 12 cSt to 75 cSt. It is also effective in environments with ambient temperatures between 86deg;F to 140deg;F.

Recommended filtration per ISO 4406: 19/16 ensures longevity and minimal contamination. Maximum back pressure on the outlet port "T" is rated at 363 PSI.

MPN: R22400309

Supplier Part Number: R22400309

Specifications

Brand
Salami Hydraulics Na Inc
Brand
Salami S.P.A
Pack Size
1.00
UOM
EA
Supplier Part Number
R22400309
Alternate Part Numbers
Alternate Part Number C1MT64
Product Weight
0.83 lbs

Similar Products

Model Number Product Description Price Action
Salami VD10A-VD12A PP Kit 1/8 NPT PortS

R22176331 VD10A Series Working Section

SALAMI VD10A-VD12A PP KIT 1/8 NPT PORTS.

Salami VD10A-VD12A R2 DETENT Kit

R22400309 VD10A Series Working Section

SALAMI VD10A-VD12A R2 DETENT KIT.

SALAMI VD10A-P02A-PRA.PRB-MLA-C2/S PARAL

S22081501 VD10A Series Working Section

SALAMI VD10A-P02A-PRA.PRB-MLA-C2/S PARAL.

SALAMI VD10A-VD12A P ( 50 - 280 ) PILOT

R22470081 VD10A Series Working Section

SALAMI VD10A-VD12A P ( 50 - 280 ) PILOT.

Salami VD10/VD12 CABLE Control

R360T0500 VD10A Series Working Section

SALAMI VD10/VD12 CABLE CONTROL.

SALAMI VD10A-P01A-PRA.PRB-MLA-C2/S PARAL

S22081391 VD10A Series Working Section

SALAMI VD10A-P01A-PRA.PRB-MLA-C2/S PARAL.

Product Questions & Answers (5)

Question by: Dean L on Mar 20, 2026, 9:11 AM
what's the fluid temperature range on this detent kit, and does it hold up alright with standard seals?
Answer by: Customer Support on Mar 22, 2026, 6:17 AM
With the stock NBR seals, the fluid temperature range runs from -4°F up to 185°F. That covers most standard hydraulic applications without needing any seal upgrades. Just make sure your system is staying within those bounds consistently, since pushing past 185°F over time is hard on any elastomer seal regardless of brand.
Question by: Janice R on Sep 17, 2025, 1:51 PM
i got a VD10A valve and need the R2 detent setup, is this kit the right one or am i mixin parts up
Answer by: Customer Support on Sep 18, 2025, 5:29 PM
This kit is labeled for the Salami VD10A Series and is specifically called out as the VD10A-VD12A R2 detent kit, part number R22400309.
Question by: Roy C on Feb 11, 2026, 7:52 PM
What kind of temperatures can this kit handle? I'm working in a pretty hot shop sometimes.
Answer by: Customer Support on Feb 13, 2026, 7:16 AM
This Salami VD10A-VD12A R2 Detent Kit is rated for fluid temperatures from -4°F to 185°F when you're using standard NBR seals. It also works in ambient temperatures between 86°F and 140°F.
Question by: Darryl J on Aug 22, 2025, 7:11 AM
what's the fluid temp range on this detent kit? running standard NBR seals and want to make sure it'll hold up in our setup
Answer by: Customer Support on Aug 24, 2025, 7:01 AM
With standard NBR seals, the operating fluid temperature range runs from -4°F up to 185°F. As long as your system stays within those bounds, the seals should hold up fine under normal working conditions.
Question by: Scott R on Dec 20, 2025, 5:35 PM
i’m swapping parts on a VD10A setup, is this detent kit the R2 one for the VD10A and VD12A sections?
Answer by: Customer Support on Dec 22, 2025, 6:02 AM
It matches the VD10A and VD12A R2 detent configuration and it is sold under MPN R22400309 for the VD10A series working section.