Salami VDM8/VD8 02A ELECTRIC Kit ESA WIT

Description & Features

This high-performance electric kit by Salami S.p.A is engineered for demanding sectional applications requiring robust flow and pressure capabilities.

The ambient temperature range of 86deg;F to 140deg;F ensures stable performance across various environments. The fluid temperature range supported by standard NBR seals extends from -4deg;F to 185deg;F.

With a flow rating of 20 GPM this kit handles fluid viscosities between 12 cSt and 75 cSt optimally with a minimum of 10 cSt and a maximum of 400 cSt. Its internal leakage rate is between 1.52 to 2.13 insup3;/min. at 2285 PSI offering high efficiency.

Designed to withstand demanding conditions it boasts a maximum operating pressure of 5100 PSI on ports "P" "A" and "B " and a maximum back pressure of 363 PSI on the outlet port T. All technical data are based on tests with mineral oil of 16 cSt viscosity and a contamination level of 19/16 per ISO 4406 standards.

MPN: Salami VD8A Series

Supplier Part Number: R23573049

Specifications

Brand
Salami Hydraulics Na Inc
Brand
Salami Hydraulics
Pack Size
1.00
UOM
EA
Key
Spool
Supplier Part Number
R23573049
Alternate Part Numbers
Alternate Part Number C1MU42
Product Weight
4.36 lbs

Similar Products

Model Number Key Product Description Price Action
Salami VDM8/VD8 02A M Spool

323511302 VD8A Series Working Section

Spool

SALAMI VDM8/VD8 02A M SPOOL.

Salami HAndLEVER. Valve HAndLE. Shaft/KN

420290180 VD8A Series Working Section

A side actuator

SALAMI HANDLEVER. VALVE HANDLE. SHAFT/KN.

SALAMI VD8A/VDM8 VA SETTING (20 TO 70 BA

796366200 VD8A Series Working Section

Main relief

SALAMI VD8A/VDM8 VA SETTING (20 TO 70 BA.

Salami VD8A/VDM8 Port Relief AR (0-420 B

796366700 VD8A Series Working Section

Main relief

SALAMI VD8A/VDM8 PORT RELIEF AR (0-420 B.

Salami R2 Detent Kit

R23500300 VD8A Series Working Section

B

SALAMI R2 DETENT KIT

Salami VDM8/VD8 02A ELECTRIC Kit ESA WIT

R23573049 VD8A Series Working Section

Spool

SALAMI VDM8/VD8 02A ELECTRIC KIT ESA WIT.

Product Questions & Answers (3)

Question by: Tammy W on Dec 20, 2025, 9:10 PM
What kind of fluid should I be running in this thing?
Answer by: Customer Support on Dec 22, 2025, 6:34 AM
Optimal fluid viscosity for this kit is between 12 cSt and 75 cSt, but it can handle between 10 cSt and 400 cSt. Keep in mind all the testing data is based on mineral oil with a 16 cSt viscosity.
Question by: Warren H on Apr 10, 2025, 8:26 PM
What kind of pressure can this electric kit actually hold up to? Running a pretty demanding circuit and need something that ain't gonna give out under load.
Answer by: Customer Support on Apr 12, 2025, 6:52 AM
Ports P, A, and B are rated for a maximum operating pressure of 5100 PSI, which puts it well into heavy-duty sectional valve territory. The outlet port T has a back pressure limit of 363 PSI, so keep that in mind when designing your return line. Flow capacity tops out at 20 GPM, and optimal viscosity runs between 12 and 75 cSt, though the kit can handle anywhere from 10 up to 400 cSt if conditions call for it.
Question by: Wayne J on Jun 6, 2025, 8:45 AM
got a system that’ll see around 4500 psi on the work ports. is this section ok with that kind of pressure?
Answer by: Customer Support on Jun 7, 2025, 2:06 PM
Pressure-wise you are within the stated limits as long as it is on ports P, A, or B, since the maximum operating pressure there is 5100 PSI. Keep the outlet port T in mind too, because the max back pressure on T is listed at 363 PSI.