This high-performance electric kit by Salami S.p.A is engineered for demanding sectional applications requiring robust flow and pressure capabilities.
The ambient temperature range of 86deg;F to 140deg;F ensures stable performance across various environments. The fluid temperature range supported by standard NBR seals extends from -4deg;F to 185deg;F.
With a flow rating of 20 GPM this kit handles fluid viscosities between 12 cSt and 75 cSt optimally with a minimum of 10 cSt and a maximum of 400 cSt. Its internal leakage rate is between 1.52 to 2.13 insup3;/min. at 2285 PSI offering high efficiency.
Designed to withstand demanding conditions it boasts a maximum operating pressure of 5100 PSI on ports "P" "A" and "B " and a maximum back pressure of 363 PSI on the outlet port T. All technical data are based on tests with mineral oil of 16 cSt viscosity and a contamination level of 19/16 per ISO 4406 standards.
MPN: Salami VD8A Series
Supplier Part Number: R23573049
Loading related products…
Specifications
Brand
Salami
Key
Spool
Sg Fluid Viscosity
12 cSt to 75 cSt Optimal, 10 cSt Minimum, 400 cSt Maximum
Sg Internal Leakage
1.52 to 2.13 cu-in/min at 2285 psi
Sg Maximum Back Pressure
363 psi on Outlet Port T
Sg Recommended Filtration
19/16 um
Suitable For Use With
VD8 02A ESA Series Control Directional Valves
Similar Products
Model Number
Suitable For Use With
Price
Action
R23576400VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
420290180VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
R23587580VD8A Series Working Section
VD8A Series 2-Spool Directional Valves and VDM8 Series 2-Spool Monoblock Directional Valves
R23500400VD8A Series Working Section
VD8A R4 Control Directional Valves and VDM8 R4 Series Monoblock Directional Valves
323511302VD8A Series Working Section
VD8A 02 Series Control Directional Valves
R20287910VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
R23577520VD8A Series Working Section
VD8A Series, VDM8 Series Directional Valves and Auxiliary Valves
796366700VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
R23575370VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
R360T0200VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
R23500300VD8A Series Working Section
VD8A R2 Control Directional Valves and VDM8 R2 Series Monoblock Directional Valves
R23576140VD8A Series Working Section
VD8A Series 01 Control Directional Valves and VDM8 Series 01 Monoblock Directional Valves
796366200VD8A Series Working Section
VD8A Series Control Directional Valves and VDM8 Series Monoblock Directional Valves
796366300
VD8A Series Hydraulic Proportional (IP) Control Directional Valves, VDM8 Series Monoblock Directional Valves
796366400
VD8A Series Hydraulic Proportional (IP) Control Directional Valves, VDM8 Series Monoblock Directional Valves
796366500
VD8A Series Hydraulic Proportional (IP) Control Directional Valves, VDM8 Series Monoblock Directional Valves
Product Questions & Answers (3)
Question by: Tammy W on Dec 20, 2025, 9:10 PM
What kind of fluid should I be running in this thing?
Answer by: Customer Support on Dec 22, 2025, 6:34 AM
Optimal fluid viscosity for this kit is between 12 cSt and 75 cSt, but it can handle between 10 cSt and 400 cSt. Keep in mind all the testing data is based on mineral oil with a 16 cSt viscosity.
Question by: Warren H on Apr 10, 2025, 8:26 PM
What kind of pressure can this electric kit actually hold up to? Running a pretty demanding circuit and need something that ain't gonna give out under load.
Answer by: Customer Support on Apr 12, 2025, 6:52 AM
Ports P, A, and B are rated for a maximum operating pressure of 5100 PSI, which puts it well into heavy-duty sectional valve territory. The outlet port T has a back pressure limit of 363 PSI, so keep that in mind when designing your return line. Flow capacity tops out at 20 GPM, and optimal viscosity runs between 12 and 75 cSt, though the kit can handle anywhere from 10 up to 400 cSt if conditions call for it.
Question by: Wayne J on Jun 6, 2025, 8:45 AM
got a system that’ll see around 4500 psi on the work ports. is this section ok with that kind of pressure?
Answer by: Customer Support on Jun 7, 2025, 2:06 PM
Pressure-wise you are within the stated limits as long as it is on ports P, A, or B, since the maximum operating pressure there is 5100 PSI. Keep the outlet port T in mind too, because the max back pressure on T is listed at 363 PSI.