S Series Geroler Motors, Up To 5190 lb-in Intermittent Torque, 963 Intermittent RPM

Description & Features

Fluid Viscosity 70 SUS at operating temperature.
Maximum Case Pressure 1500 PSI.
Maximum Operating Temperature 180° F.
Recommended Break-In To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.
Recommended Filtration Per ISO Cleanliness Code, level 18/13.
Recommended Fluids Premium quality, anti-wear type hydraulic fluid.

Products

Product Questions & Answers (1)

Question by: Janet P on Jan 21, 2026, 8:53 AM
What kind of hydraulic fluid do these motors need? Gotta make sure I'm using the right stuff.
Answer by: Customer Support on Jan 22, 2026, 11:34 AM
These S Series Geroler motors require a premium quality, anti-wear type hydraulic fluid. It should be maintained at a minimum viscosity of 70 SUS at operating temperature, and the fluid cleanliness maintained to ISO Cleanliness Code level 18/13.